dated June 22, and all previous versions of this specification. Approved by the AISC Committee on Specifications. AMERICAN INSTITUTE. published. Like the edition, the edition is not a complete revision but does add important changes and updates. It is the result of the. SEPTEMBER MODERN STEEL CONSTRUCTION. A revised slip resistance formula for bolted connections is among the changes that will.

Author:RALEIGH SIFFORD
Language:English, Spanish, Arabic
Country:Marshall Islands
Genre:Science & Research
Pages:387
Published (Last):06.04.2016
ISBN:669-1-66646-839-9
Distribution:Free* [*Registration needed]
Uploaded by: MARKETTA

68268 downloads 126779 Views 36.57MB PDF Size Report


Aisc 2010 Pdf

for Structural Steel Buildings (ANSI/AISC ) (Fourth Printing. Format: PDF Publication Date: East Randolph, Suite , Chicago, IL, Fifth Printing: April Specification for This edition of the AISC Specification is dedicated to the memory of Dr. Lynn S. Beedle,. University. Specification for Structural Steel Buildings, June 22, (This Preface is not part of ANSI/AISC , Specification for Structural Steel.

This book or any part thereof must not be reproduced in any form without the written permission of the publisher. The information presented in this publication has been prepared in accordance with recog- nized engineering principles and is for general information only. While it is believed to be accurate, this information should not be used or relied upon for any specific application without competent professional examination and verification of its accuracy, suitability and applicability by a licensed professional engineer, designer or architect. The publication of the material contained herein is not intended as a representation or warranty on the part of the American Institute of Steel Construction or of any other person named herein, that this information is suitable for any general or particular use or of freedom from infringement of any patent or patents. Anyone making use of this information assumes all liability arising from such use. Caution must be exercised when relying upon other specifications and codes developed by other bodies and incorporated by reference herein since such material may be modified or amended from time to time subsequent to the printing of this edition. The Institute bears no responsibility for such material other than to refer to it and incorporate it by reference at the time of the initial publication of this edition. Printed in the United States of America This Specification is based upon past successful usage, advances in the state of knowledge, and changes in design practice. Subscribe to view the full document.

Plans, sections and elevations showing layout, dimensions and levels of all concrete members within Location of all holes, chases, pockets, fixings Section drawings represents the material of construction to be used, heights and measurement of the different components of buildings, type of structural components such as type of slab , etc.

The list of abbreviations used in a set of structural drawings varies from office to office. The standards are very in depth and include consideration of materials and workmanship requirements, structural matters, fire safety, sound insulation, energy conservation and access to and use of buildings. The Architect designs the building keeping all the functional aspects in mind that are to be incorporated into the design and then they are executed by a Civil or Structural Engineer.

8. Steel Design-AISC

Concrete frame structures are a very common - or perhaps the most common- type of modern building internationally. Details - specification - sizing - construction cuts No matter what the project requires, we have the experience and technology to provide it.

As a result, it was also possible to determine that the New York Historical Society had archived drawings for a number of different buildings designed by Gilbert, including the National State Bank Building. Find and download ready made construction civil engineering structural detailed drawings for reinforced concrete design, steel frame design and timber wooden design. Jim shows examples that include the details for the building's foundation and roof framing, and explains that structural drawings may be drawn by the architect or a structuralengineer.

Erection Bracing Drawings. These What does a structural engineer typically do? These drawings show the support system of the building like how the building is standing, what are its structural components, what is the strength of the building and how beams, columns, stairs, slabs etc. The column line may be straight or curved as shown in the structural design drawings. Column offsets are taken from the column line.

Absolute Steel will not begin work on your engineered plans until your invoice has been paid in full. Structural Framing Details. However, practice bulletins may be issued from time to time to clarify statements made herein or to add Architectural drawings gives the external view or aesthetic view of the building or construction and provides the location of columns, walls, staircases and ducts etc.

Its represents the drawing when the building is cut through a vertical plane. With reference to these Codes the structural engineer, using both the computer and hand calculations, produces the structural design of the building, bridge or other framework. Your finished drawings will need to be approved by either your architect or your engineer, depending upon their complexity.

Structural Drafting - Structural Drawings Samples. Each structural engineering office uses their own set of plan symbols; however, the symbols below are fairly standard at many offices. The direction of the plane through which the section is cut is often represented on plan drawings and elevations by a line of long and short dashes, called a section plane.

One can get a clear idea about working of any building construction project. General civil drawings comprises many set of drawings of which architectural drawings and structural drawings have prime importance apart from several other drawings like fire fighting drawings, plumbing drawing, electrical drawings etc. Unless you are responsible for framing or steel work, it is usually sufficient to understand where columns are located and how roof and floor framing will be constructed.

OSD is an India based privately owned firm offering world class structural drawing services to all international and domestic clients scattered all over the globe.

We also have an article that will help you identify structural drawing symbols. Horizontal members of this frame are called beams, and vertical members are called columns. In our current work we Real structures or parts of structures and typical engineering drawings are used in these works as much as possible so that the student can transition into the practice of structural engineering with a minimum of challenge.

We excel in very complex buildings and structures. View Details. Be sure to check the front section of the drawing set for the abbreviations used within.

AISC Formulas 2010.pdf

Structural detail drawings prepared by our licensed professional structural engineers depending on the materials used typically include a masonry bearing and shear wall details, including masonry unit and mortar strengths, details of reinforcing, support of loads, lintels and grouting procedures; A brief tour of a set of structural design drawings for a building from the perspective of a structural engineer. The top of foundation walls is defined at all points around the building.

Available formats for download in dwg, dxf and pdf format all in a single zip file. Right Side Elevation. The details are arranged and numbered in categories with regard to their respective structural application, such as foundations, floors, roofs, walls, and other particular parts of a building. We follow the standards as per client's requirement for text style, dimension style and layers. The intent of this video is to provide insight into the way an expert decodes the drawings in order to assist students in developing this skill.

Cover Plates No changes have been made to this section. Built-Up Beams No changes have been made to this section. Unbraced Length for Moment Redistribution new section The contents of this section have been moved from Appendix 1, Section 1. The variable for the limiting laterally unbraced length for plastic analysis, Lpd, has been changed to the limiting laterally unbraced length for eligibility for moment redistribution in beams, Lm.

When determining the equation for the web plate shear buckling coefficient, the term unstiffened web has been changed to web without transverse stiffeners.

The web plate shear buckling coefficient equation for webs with transverse stiffeners has been given the equation number G Transverse Stiffeners A new variable, Ist, has been assigned to the moment of inertia of transverse stiffeners. The minimum of this moment of inertia has been moved from the text to Equation G In Equation G, the variable, a, has been changed to b.

The provision for when lateral bracing is attached to a stiffener has been removed. Transverse Stiffeners The first limiting condition in Section G3. The equation for the second limiting condition has been changed as follows: The following equation has been added to this section: The following relationship has been added: The definition of the design wall thickness, t, has been added to this section. A definition of, b, has been added to this section.

Doubly and Singly Symmetric Members Subject to Flexure and Tension The term tensile strength has been changed to axial strength in the variable definitions. The following condition has been added to this section for compact members: The equation for out of plane buckling has been changed as follows: This section has been reorganized to improve clarity. The definitions of h and t have been added to this section. The design and allowable torsional strength has been changed to available torsional strength.

Concrete and Steel Reinforcement In the Specification the provisions of the ACI are applied in the absence of an applicable building code.

The Specification stipulates that the ACI applies in addition to an applicable building code. Several new exceptions and limitations are given for the use of ACI A user note is included in this section that states it is the intent of the Specification for the reinforced concrete portion of a composite section to be detailed using the noncomposite provisions of ACI Nominal Strength of Composite Sections Added to this section is the statement that local buckling effects do not need to be considered for encased composite members.

Strain Compatibility Method No changes have been made to this section. Material Limitations Structural steel has been included in the list for material limitations of this section. The provision that higher strength materials are permitted when justified by testing or analysis has been removed.

Classification of Filled Composite Sections for Local Buckling This section covers the new limiting width-to-thickness ratios for filled composite sections.

These sections qualify as compact, noncompact or slender for both compression and flexure. The ratios and limits for filled composite members are located in Tables I1. Encased Composite Members I2. Limitations Several new requirements have been added to Section I2. A minimum size of reinforcement is given along with the maximum spacing of ties based on reinforcement size and least column dimension. A user note is included referring to ACI for additional tie and spiral reinforcement requirements.

Compressive Strength The provisions of this section now specifically apply to axially loaded doubly symmetric encased composite members. The variable for nominal axial compressive strength without length effects, Po, has been changed to Pno. The variable for the minimum yield stress of the reinforcing bars, Fyr, has been changed to Fysr. Added is a statement that the available compressive strength need not be less than that of the bare steel member.

Load Transfer This section now refers to Section I6 for load transfer requirements for encased composite members. Detailing Requirements Several detailing requirements have been removed from this section including the total number of longitudinal reinforcing bars and the transverse reinforcement spacing.

The provision for clear cover to reinforcing steel has been changed from a minimum 1. Shear connector detailing requirements have been moved to Section I6. Noncompact and slender members are now allowed by the provisions without justification by testing or analysis. The width-to-thickness ratios for local buckling are now contained in Table I1.

The equation for the available compressive strength of a compact member has been changed as follows: A statement that the available compressive strength need not be less than that of the bare steel member has been added. Load Transfer This section now refers to Section I6 for load transfer requirements for filled composite members. General I3. Effective Width No changes have been made to this section. Strength During Construction No changes have been made to this section.

Positive Flexural Strength No changes have been made to this section. Negative Flexural Strength No changes have been made to this section. The variable for the area of adequately developed longitudinal reinforcing steel within the effective width of the concrete, Ar, has been changed to Asr. The subsections covering the strength, number and placement and spacing or steel headed stud anchors have been moved to Section I8. Encased Composite Members In the Specification this section contained provisions for both encased and filled members.

In the Specification the provisions for filled members have been moved to Section I3. The LRFD resistance factor and ASD safety factor if steel anchors are provided using the plastic stress distribution on the composite section or strain compatibility methods have been changed as follows: Limitations Filled composite sections are now classified for local buckling using the limiting width-to-thickness ratios in Table I1.

Flexural Strength New equations have been provided for the calculation of the nominal flexural strength for compact, noncompact and slender filled composite members. Filled and Encased Composite Members The available shear strength of an encased composite member is now allowed to be calculated using the nominal shear strength of the steel section alone.

The available shear strength for filled composite members is now allowed to be calculated based on the nominal shear strength of the steel section plus the nominal shear strength of the reinforcing steel. The resistance factor for LRFD and safety factor for ASD are given for calculating the nominal shear strength of the reinforced concrete portion alone or the reinforced concrete with the steel section, they are as follows: Additionally, the interaction equations of Section H1.

General Requirements This section combines the axial load transfer for both the encased and filled axially loaded composite members. These provisions now apply to filled members. External Force Applied to Concrete The statement: External Force Applied Concurrently to Steel and Concrete This new section gives the provision for an encased or filled composite member with force applied concurrently to the concrete and steel sections.

In the bearing strength equation the variable for nominal bearing strength of concrete, Pp, has been changed to nominal strength of force transfer mechanism, Rn and the variable for loaded area, AB, has been changed to loaded area of concrete, A1. Shear Connection This new section gives the provisions for force transfer by shear connection in filled and encased composite members. Direct Bond Interaction This new section gives equations for force transfer in filled rectangular and round steel sections by direct bond interaction.

Detailing Requirements I6. Encased Composite Members The provisions for steel anchor detailing for encased composite members have been moved from Section I2.

The distribution has changed from at least 2. The provision for the maximum connector spacing of 16 in. Filled Composite Members The provisions for steel anchor detailing for filled composite members have been moved from Section I2. The distribution of at least 2.

Index of /~ahvarma/CE 579

No additional changes have been made to this section. The cross-sectional area of stud shear connector, Asc, has been changed to the cross-sectional area of steel headed stud anchor, Asa. For steel headed stud anchors welded directly to the steel shape the position effect factor, Rp, has been changed from 1. The footnote in the user note which gives the qualifications for a no decking condition has been removed. The channel shear connecter is now defined as a hot-rolled channel anchor.

The length of channel shear connector, Lc, has been changed to the length of channel anchor, la. Required Number of Steel Anchors No changes have been made in this section.

Detailing Requirements Added to this section is a provision for the minimum distance from the center of an anchor to a free edge in the direction of the shear force, which is 8 in. Steel Anchors in Composite Components This new section covers the provisions for other types of composite components not covered in other sections of this chapter. Shear Strength of Steel Headed Stud Anchors in Composite Components This section covers the shear strength of a steel headed stud anchor when concrete breakout is not an applicable limit state.

Tensile Strength of Steel Headed Stud Anchors in Composite Components This section covers the tensile strength of a steel headed stud anchor based on the distance from the anchor to a free edge and the center-to-center anchor spacing. Strength of Steel Headed Stud Anchors for Interaction of Shear and Tension in Composite Components This section covers the nominal strength for interaction between shear and tension for a steel headed stud anchor.

Detailing Requirements in Composite Components This section gives the provisions for the minimum cover, minimum and maximum spacing of steel headed stud anchors and maximum spacing of steel channel anchors for composite components.

Design Basis No changes have been made to this section. Simple Connections No changes have been made to this section. Compression Members with Bearing Joints The following sentence has been added to improve clarity: Weld Access Holes Beam cope provisions have been removed from this section. The minimum height requirement for access holes has been changed from 1 in. Placement of Welds and Bolts No changes have been made to this section.

Bolts in Combination with Welds No changes have been made to this section. Limitations on Bolted and Welded Connections Slip-critical has been removed from the list of required joints in this section. Groove Welds J2. Effective Area No changes have been made to this section. Limitations No changes have been made to this section. Fillet Welds J2. Limitations The minimum length requirements for fillet welds designed on the basis of strength have been changed to incorporate the actual length of the weld instead of its effective length.

In addition to being used to transmit shear in lap joints, fillet welds in holes or slots are now permitted to be used to resist loads perpendicular to the faying surface in lap joints.

Plug and Slot Welds J2. Strength The limit state of yielding is no longer applicable when determining the base material strength and the weld metal strength. See Table J2. Sections J2. Combination of Welds No changes have been made to this section. Filler Metal Requirements No changes have been made to this section. Mixed Weld Metal No changes have been made to this section.

High-Strength Bolts High-strength bolts in the Specification are now grouped according to material strength as follows: Bolts are permitted to be installed to the snug-tight condition when used in bearing type connections, except as noted in Section E6 or Section J1. These exceptions were not listed in the Specification. The definition of the snug-tight condition has been simplified to the tightness required to bring the connected plies into firm contact. A user note has been added to this section stating that there are no specific minimum or maximum tension requirements for snug-tight bolts and fully pretensioned bolts such as ASTM F or F are permitted unless specifically prohibited on design drawings.

BC, A Gr. BD, or A bolts and threaded rods in slip-critical connections, the bolt geometry to be compared to the bolt geometry required by the RCSC Specification now includes the thread pitch and the thread length in addition to the head and nut s.

The conditions under which a single hardened washer conforming to ASTM F shall be used in lieu of the standard washer and its associated user note have been moved to Section J3. The paragraph referencing Section J3. It still references Appendix 3 requirements, but now applies to high-strength bolts subject to tensile fatigue loading. It now only applies to A bolts when determining the nominal shear strength in bearing-type connections.

This was footnote [f] in the Specification. Values in Table J3. The following table lists the changes per case. Size and Use of Holes The conditions under which a single hardened washer conforming to ASTM F shall be used in lieu of the standard washer and its associated User Note have been moved to this section. Minimum Spacing A user note has been added to this section, stating that ASTM F anchor rods may be furnished in accordance to product specification with a body diameter less than the nominal diameter.

Minimum Edge Distance No changes have been made to this section.

References | Short Span Steel Bridge Alliance | Short Span Bridges

Maximum Spacing and Edge Distance A user note has been added to this section stating that dimensions which are listed just before the user note do not apply to elements consisting of two shapes in continuous contact. This change is consistent with the reorganization of Table J3.

A user note has been added to this section stating that the strength of a bolt group be taken as the sum of the effective strengths of the individual fasteners, where the effective strength of an individual fastener may be taken as the lesser of the fastener shear strength based on the provisions of this section or that of the bearing strength at the bolt hole from the provisions of Section J3.

Combined Tension and Shear in Bearing-Type Connections The following has been added to the definition of frv to improve clarity: High-Strength Bolts in Slip-Critical Connections The available strength for slip-critical connections is now based on the limit state of slip and the limit states of bearing-type connections this limit state was based on serviceability and slip in the Specification.

The paragraph outlining when to design slip-critical connections based on the limit states of serviceability and slip has been removed. The following table summarizes the new provisions for slip-critical connection strength. This factor is taken as 1.

Where bolts have not been added to distribute the load in the filler for two or more fillers between connected parts, this variable is taken as 0. Combined Tension and Shear in Slip-Critical Connections The variable for the number of bolts carrying the applied tension in a slip- critical connection, Nb, has been changed to nb.

The variable for the factor to be multiplied to the available slip resistance per bolt, ks, has been changed to ksc. Bearing Strength at Bolt Holes A user note has been added to this section: The strength of the bolt group is the sum of the effective strengths of the individual fasteners, where the effective strength of an individual fastener is the lesser of the fastener shear strength per Section J3.

The variable used for the clear distance, in the direction of the force, between the edge of the hole and the edge of the adjacent hole or edge of the material, Lc, has been changed to lc. Special Fasteners No changes have been made to this section. Tension Fasteners No changes have been made to this section.

Strength of Elements in Tension A user note has been added to this section stating that the effective net area of the connection plate may be limited due to stress distribution as calculated by methods such as the Whitmore Section. Strength of Elements in Shear No changes have been made to this section.

Block Shear Strength No changes have been made to this section. Strength of Elements in Compression No changes have been made to this section. The number of errors in future editions will not decrease if they continue their attempts to make an exact science out of what should be conservatively empirical.

The errata that got me all flustered was for the whole manual. I agree that the shorter code cycles would be a legitimate explanation for all these errors. For a working engineer, I ordered the 13th Edition when the first printing came out. I did this mainly for the interest I had in it and now, with all these errors I feel like "next time" I'll wait for the later editions.

Usually the building codes come in slower so the new AISC edition isn't usually needed right away. But that puts AISC's cash flow in a slower rate so would that initiate more errors since they would have less cash for checkers early on if we all waited for the third or fourth printing? Or would waiting delay the subsequent printings?